Posted in

How to troubleshoot a glass tempering furnace that is not heating properly?

Hey guys, let’s cut to the chase – if your glass tempering furnace is acting up and not heating like it should, you’re probably staring at a stack of half-tempered glass, missed deadlines, and a whole lot of stress. I’ve been in the glass tempering game for over 12 years, running a small but tight-knit team that supplies, installs, and services these furnaces (yeah, that’s us – we’re the guys you call when the thing’s screaming for help and your mechanic’s clueless), so I’ve seen every dumb, annoying, and sometimes downright weird heating issue you can throw at a furnace. Most of the time, it’s not some crazy, unfixable electrical gremlin – it’s something you can diagnose and fix in an hour (or less) if you know what to check first. Let’s walk through this step by step, no jargon, no fancy lingo, just real stuff we actually deal with on a weekly basis. Glass Tempering Furnace

First, let’s set the baseline: glass tempering furnaces need consistent, even heat (usually between 600-700°C, depending on the glass thickness) to turn raw float glass into safe, durable tempered stuff. If it’s not hitting that temp, or it’s hot in one spot and freezing in another, that’s when you start getting warped glass, spots that won’t temper right, and tons of scrap. The first thing I tell every new customer is: before you start tearing apart wiring or calling a tech (which costs you $200 an hour and waits 3 days), do a quick visual check of the basics. I once had a customer blame a “broken heating element” for 3 days, only to find the main breaker in the building had tripped – like, the whole shop power was out, and he didn’t even notice because the lights were on somewhere else. Don’t be that guy.

Start with the power supply. This is the single most common issue, and it’s 90% operator error or a bad part that’s easy to miss. If your furnace is a resistance-based model (which almost all commercial ones are), it runs on heavy-duty electrical power – usually 3-phase, 240 or 480 volts. First, check the main disconnect switch – yeah, the big metal box on the side of the furnace. I’ve seen those get bumped shut by forklifts, or someone yank the cord and not turn it all the way. Next, check the circuit breakers for the heating zone controllers. A half-trip breaker is a weird one – it’ll look like it’s on, but it’s only sending half the power, so you get weak heat. If you have a multimeter (you should, every fab shop does), test the line voltage at the furnace’s power input. If it’s 10-15% below the rated voltage, that’s a problem. Also, check the connections at the breaker and the furnace terminals – loose wires over time get corroded, cause resistance, and drop voltage. We recommend tightening these every 6 months, but half the guys skip that. Pro tip: if you just had a power outage or a shop upgrade, that’s the first thing to check – I swear, 2 out of 5 heating issues after an outage are power-related.

Next up, heating elements. These are the workhorses, and they take a beating – thermal expansion and contraction every time the furnace cycles, dust and glass fumes building up, sometimes even a small fire that takes out a section. A lot of guys think if one element is out, the whole furnace is dead, but no – usually, zones are split into sections (top and bottom, usually 10 or so zones total), so if one small element goes out, that zone is cold, and you get uneven heat. How do you check this? Once the furnace is at operating temp (and locked out, safety first), pull the access panel and visually inspect the elements. Look for broken coils, blackened spots, or sections that are sagging (that means they’re burned out). If you see a broken element, turn off power, disconnect the leads, and test with an ohmmeter – if there’s no continuity, it’s bad. Here’s a pro tip from our techs: don’t wait for elements to break. They usually last 2-5 years, depending on usage, and we see so many customers wait until they fail mid-job, leading to a $1,000 element and $5,000 in scrap glass. We sell replacement elements for all our furnaces, and we ship next day if you need them fast. Also, clean the elements once a month – glass dust and fumes coat them, insulate them, and make them less efficient. A quick wipe with a dry cloth (after power is off, duh) or a special non-corrosive cleaner will boost their heat output by 10-15%.

Then there’s the thermocouples. These are the temperature sensors that tell the furnace’s controller how hot it is, right? If a thermocouple is bad, the controller doesn’t get the right temp reading, so it turns the elements on too low (or too high, but heating issues are usually low). This is another super common, easy-to-fix problem. Thermocouples are small, metal probes, usually screwed into the furnace walls, one per zone. They get dirty, bent, or just wear out over time. How to test them? First, check the connection at the controller – loose wires here will give a wrong reading. If that’s fine, take a new thermocouple (we sell those too) and swap it with a working one from another zone. If the problem moves to that zone, then the old thermocouple is garbage. Also, if the thermocouple is coated in glass gunk, that’s a big issue – the gunk insulates it, so it can’t read the actual furnace temp. Scrub it gently with a wire brush (again, power off!) to get the gunk off, and that often fixes it. I once had a customer tell me his furnace was “dead cold” when it was set to 650°C, turned out a thermocouple was bent and touching the furnace wall, so it was reading the wall temp instead of the air in the zone. That’s a $0 fix, not a $500 tech call.

Now, if you’ve checked power, elements, and thermocouples, the next culprit is usually the furnace’s insulation or air circulation. Wait, air circulation in a tempering furnace? Yeah, most people don’t realize these are convection furnaces – they use fans to blow hot air evenly over the glass. If the insulation is failing, you’re losing heat out the walls, so the elements have to work harder, and they still can’t hit temp. How do you check insulation? Walk the outer walls of the furnace when it’s running – if any spots are hot to the touch (not just warm, hot enough you can’t leave your hand there), that’s insulation that’s gone bad. Insulation usually lasts 5-7 years, depending on how often you cycle the furnace. We supply insulation for our furnaces, and replacing it is a big job, but way cheaper than running a furnace that wastes 30% of its heat. Also, check the circulation fans – the big metal blades inside the furnace. If they’re dirty, bent, or the motor is dying, they won’t blow air evenly, so you get hot spots and cold spots. Listen for weird noises from the fan motor (squealing, grinding) when the furnace is running – that’s a sign the bearings are shot, and we can send you a replacement motor fast. A few months back, a customer had his furnace only heat on the top half, turned out a fan blade had broken off, so all the hot air was blowing only to the top zone. He tried replacing elements and thermocouples for a week before we figured it out – don’t skip checking the fans.

Another weird one I’ve seen? Controller software glitches. Yeah, even our furnaces (and all the big brands) have digital controllers that can bug out sometimes. It’s not the hardware, it’s the little software hiccup. If you’ve checked all the physical parts, try resetting the controller – power it off, wait 5 minutes, turn it back on. Most of the time, that fixes it. If not, check for any updates – we push small updates to our controllers every 6 months, mostly fixing temp reading and heating zone issues. Sometimes if there was a power surge, the controller’s settings get messed up – like, someone changed the temp setpoint by accident, or a zone was turned off. We’ve had guys blame the whole furnace for heating issues only to find someone on the shop floor accidentally disabled a zone setting.

Now, let’s talk about when you shouldn’t mess around. If you’ve gone through all these steps and you still can’t figure it out, or if the issue is with the main power distribution panel, or big wiring runs, or the main heating transformer – call a pro. But not just any pro – call the people who sold you the furnace, or a reputable service team that specializes in glass tempering furnaces. A lot of general electricians don’t know the specific electrical needs of these furnaces, so they’ll either charge you too much or mess something up worse. And don’t wait too long – a furnace that’s not heating right will ruin a ton of glass, which is way more expensive than a service call.

Wait, one last thing: regular maintenance is way cheaper than fixing issues after they happen. Every month, do a 15-minute check: power connections, thermocouple condition, element cleanliness, fan noises. Every 6 months, do a deep clean of elements and insulation check. Our team does free maintenance checklists for all our customers, no extra charge, because we know the headaches come when you skip that.

At the end of the day, most heating issues with glass tempering furnaces are simple, avoidable problems. You don’t need a PhD in electrical engineering to fix 90% of them – you just need to know where to look first. If you’re still stuck after going through all these steps, or if you’re ready to upgrade your current furnace (or get a new one that doesn’t have all these annoying issues), hit us up. We supply reliable, easy-to-maintain glass tempering furnaces, and our service team is on call 24/7 for any issues, big or small. We don’t do vague quotes, we don’t overcharge, and we know the glass fab game like the back of our hands. Don’t let a bad heating furnace kill your production – get in touch, and we’ll get you sorted.

Glass Cutting Machine References
Glass Processing Technology. (2021). Troubleshooting common resistance heating issues in industrial furnaces. International Glass Journal.
Tempering Furnace Maintenance Guide. (2022). Glass Association of North America.
Smith, J. (2020). Field observations of glass tempering furnace heating anomalies. Journal of Industrial Glass Equipment.


Foshan Sky Glass Co., Ltd.
We are one of the most experienced glass tempering furnace manufacturers and suppliers in China. With a professional production team, we are able to meet the needs of the majority of our customers. Please feel free to wholesale advanced glass tempering furnace for sale here from our factory. Customized orders are welcome.
Address: Jian Mei Business Center, Nan Hai Town, Fo Shan
E-mail: skyglassmanager18@gmail.com
WebSite: https://www.sky-glassdz.com/